Preview 3 and Preview G Battery Replacement

Successfully replace backup batteries for encoders and relocation batteries

By the Call Center Technical Support Team at Mazak Optonics Corp.

There are two different types of backup batteries—batteries for encoders and relocation batteries—that need to be replaced every 2,000 hours or when warning alarms appear. Follow the instructions below to successfully change these batteries.

Important Note

Prior to beginning the battery replacement process for encoders and relocation batteries, please note the following:

  • Always change batteries with the power on
  • Ensure all axes (X, Y, Z, U, W, 2PC) are in the home position

Changing Relocation Batteries

Materials: 2 Alkaline “D” batteries and a screw driver

Figure 1

 1.  Turn the breaker ON and the NC ON.

2. Check the electric cabinet door of the R.D. battery box.

3. Remove the lid of the battery box.

4. Remove the old batteries and install the new batteries.

5. Replace the lid and fasten the screws.

6. Turn OFF the NC first, then the breaker. Next, turn the breaker ON first, then the NC.

Confirm that the following NC alarms are not displayed.

  • R.D. Battery Not Mounted
  • R.D. Low Battery
  • R.D. Battery Change Time Exceeded

Once confirmed, the battery change is successfully completed. 

Changing Axis Encoder Batteries

Materials: 3 Alkaline “D” batteries and a screw driver

1. Check to see that the main power breaker is in the ON position. The status of the NC power supply is not relevant at this time.

2. Remove the lid of the battery box which is fastened with 4 screws.

3. Replace the three alkaline batteries with new ones.

4. Replace the lid and fasten the screws.

5. Follow the steps below to ensure the batteries are replaced properly. 

  • Open the  ALARM  screen
  • Press the  RESET  key on the NC unit
  • After pressing the  RESET  key, check to make sure that the alarms 5002, 5102, 5202, 5302, and 5602 are not displayed

If the alarms are present after completing the steps outlined above, try the battery replacement procedure again without turning off the main power breaker.

Note: If the main power breaker is set to OFF and the batteries are not replaced properly, it will become impossible for the machine to operate. To restore the machine to normal operation, servicing by Mazak will be required. 

For more information, please contact Mazak customer support at 1-888-MAZAK-US or email service@mazaklaser.com.

Discover More Tips

About Mazak Optonics Corporation

Mazak Optonics Corporation is a major supplier of laser-cutting systems, offering 50 laser models and leading the industry in the implementation of emerging laser technologies. The company’s 50,000 sq. ft. North American Headquarters are located in Elgin, Illinois, and feature a 30,000 sq. ft. laser technology center housing up to 18 machines for demonstrations and training. Mazak Optonics is part of Yamazaki Mazak Corporation (Oguchi, Japan), the global leader for the manufacture of machine tools and systems for the precision machining of metal parts, including CNC turning centers, horizontal and vertical machining centers, Multi-Tasking machining centers, turnkey cells and software solutions. The North American Headquarters for Yamazaki Mazak are located in Florence, Kentucky. For more information on Mazak Optonics’ products and solutions, visit www.mazakoptonics.com, email sales@mazaklaser.com or call 847.252.4500.